14 research outputs found

    Advances in transdermal insulin delivery

    Get PDF
    Insulin therapy is necessary to regulate blood glucose levels for people with type 1 diabetes and commonly used in advanced type 2 diabetes. Although subcutaneous insulin administration via hypodermic injection or pump-mediated infusion is the standard route of insulin delivery, it may be associated with pain, needle phobia, and decreased adherence, as well as the risk of infection. Therefore, transdermal insulin delivery has been widely investigated as an attractive alternative to subcutaneous approaches for diabetes management in recent years. Transdermal systems designed to prevent insulin degradation and offer controlled, sustained release of insulin may be desirable for patients and lead to increased adherence and glycemic outcomes. A challenge for transdermal insulin delivery is the inefficient passive insulin absorption through the skin due to the large molecular weight of the protein drug. In this review, we focus on the different transdermal insulin delivery techniques and their respective advantages and limitations, including chemical enhancers-promoted, electrically enhanced, mechanical force-triggered, and microneedle-assisted methods

    Glucose-Responsive Insulin and Delivery Systems: Innovation and Translation

    Get PDF
    Type 1 and advanced type 2 diabetes treatment involves daily injections or continuous infusion of exogenous insulin aimed at regulating blood glucose levels in the normoglycemic range. However, current options for insulin therapy are limited by the risk of hypoglycemia and are associated with suboptimal glycemic control outcomes. Therefore, a range of glucose-responsive components that can undergo changes in conformation or show alterations in intermolecular binding capability in response to glucose stimulation has been studied for ultimate integration into closed-loop insulin delivery or “smart insulin” systems. Here, an overview of the evolution and recent progress in the development of molecular approaches for glucose-responsive insulin delivery systems, a rapidly growing subfield of precision medicine, is presented. Three central glucose-responsive moieties, including glucose oxidase, phenylboronic acid, and glucose-binding molecules are examined in detail. Future opportunities and challenges regarding translation are also discussed

    Glucose-responsive oral insulin delivery for postprandial glycemic regulation

    Get PDF
    Controlling postprandial glucose levels for diabetic patients is critical to achieve the tight glycemic control that decreases the risk for developing long-term micro- and macrovascular complications. Herein, we report a glucose-responsive oral insulin delivery system based on Fc receptor (FcRn)-targeted liposomes with glucose-sensitive hyaluronic acid (HA) shell for postprandial glycemic regulation. After oral administration, the HA shell can quickly detach in the presence of increasing intestinal glucose concentration due to the competitive binding of glucose with the phenylboronic acid groups conjugated with HA. The exposed Fc groups on the surface of liposomes then facilitate enhanced intestinal absorption in an FcRn-mediated transport pathway. In vivo studies on chemically-induced type 1 diabetic mice show this oral glucose-responsive delivery approach can effectively reduce postprandial blood glucose excursions. This work is the first demonstration of an oral insulin delivery system directly triggered by increasing postprandial glucose concentrations in the intestine to provide an on-demand insulin release with ease of administration

    Insulin-Responsive Glucagon Delivery for Prevention of Hypoglycemia

    Get PDF
    Hypoglycemia, the state of abnormally low blood glucose level, is an acute complication of insulin and sulfonylurea therapy in diabetes management. Frequent insulin dosing and boluses during daily diabetes care leads to an increased risk of dangerously low glucose levels, which can cause behavioral and cognitive disturbance, seizure, coma, and even death. This study reports an insulin-responsive glucagon delivery method based on a microneedle (MN)-array patch for the prevention of hypoglycemia. The controlled release of glucagon is achieved in response to elevated insulin concentration by taking advantage of the specific interaction between insulin aptamer and target insulin. Integrating a painless MN-array patch, it is demonstrated that this insulin-triggered glucagon delivery device is able to prevent hypoglycemia following a high-dose insulin injection in a chemically induced type 1 diabetic mouse model

    Validation of distinct type 2 diabetes clusters and their association with diabetes complications in the DEVOTE, LEADER and SUSTAIN-6 cardiovascular outcomes trials

    Get PDF
    Aims: To validate the clusters of Swedish individuals with recent-onset diabetes at differential risk of complications, which were identified in a previous study, in three global populations with long-standing type 2 diabetes (T2D) who were at high cardiovascular risk, and to test for differences in the risk of major diabetes complications and survival endpoints. Materials and methods: We assigned participants from recent global outcomes trials (DEVOTE [n = 7637], LEADER [n = 9340] and SUSTAIN-6 [n = 3297]) to the previously defined clusters according to age at diabetes diagnosis, baseline glycated haemoglobin (HbA1c) and body mass index (BMI). Outcomes were assessed using Kaplan–Meier analysis and log-rank tests. Results: The T2D clusters were consistently replicated across the three trial cohorts. The risk of major adverse cardiovascular events and cardiovascular death differed significantly, in all trials, across clusters over a median follow-up duration of 2.0, 3.8 and 2.1 years, respectively, and was highest for the cluster of participants with high HbA1c and low BMI (P < 0.05 in DEVOTE and LEADER). In LEADER and SUSTAIN-6, the risk of nephropathy differed across clusters (P < 0.0001 and P = 0.003, respectively). The risk of severe hypoglycaemia differed in DEVOTE (P = 0.006). Conclusions: Previously identified clusters can be replicated in three geographically diverse cohorts of long-standing T2D and are associated with cluster-specific risk profiles for additional clinical and survival outcomes, providing further validation of the clustering methodology. The external validity and stability of clusters across cohorts provides a premise for future work to optimize the clustering approach to yield T2D subgroups with maximum predictive validity who may benefit from subtype-specific treatment paradigms

    Characteristics and Delivery of Diabetes Shared Medical Appointments in North Carolina

    Get PDF
    BACKGROUND Successful diabetes care requires patient engagement and health self-management. Diabetes shared medical appointments (SMAs) are an evidence-based approach that enables peer support, diabetes group education, and medication management to improve outcomes. The purpose of this study is to learn how diabetes SMAs are being delivered in North Carolina, including the characteristics of diabetes SMAs across the state.METHOD Twelve health systems in the state of North Carolina were contacted to explore clinical workflow and intervention characteristics with a member of the SMA care delivery team. Surveys were used to assess intervention characteristics and delivery.RESULTS Diabetes SMAs were offered in 10 clinics in 5 of the 12 health systems contacted with considerable heterogeneity across sites. The majority of SMAs were open cohorts (80%), offered monthly (60%) for 1.5 hours (60%). SMAs included a mean of 7.5 ± 3.4 patients with a maximum of 11.2 ± 2.7 patients. Survey data revealed barriers (cost-sharing and provider buy-in) to, and facilitators (leadership support and clinical champions) of, clinical adoption and sustained implementation.LIMITATIONS External validity is limited due to the small sample size and geographic clustering.CONCLUSION There is significant heterogeneity in the delivery and characteristics of diabetes SMAs in North Carolina with only modest uptake across the health systems. Further research to determine best practices and effectiveness in diverse, real-world clinical settings is required to inform implementation and dissemination efforts

    Bioresponsive Microneedles with a Sheath Structure for H2O2 and pH Cascade-Triggered Insulin Delivery

    Get PDF
    Self-regulating glucose-responsive insulin delivery systems have great potential to improve clinical outcomes and quality of life among patients with diabetes. Herein, an H2O2-labile and positively charged amphiphilic diblock copolymer is synthesized, which is subsequently used to form nano-sized complex micelles (NCs) with insulin and glucose oxidase of pH-tunable negative charges. Both NCs are loaded into the crosslinked core of a microneedle array patch for transcutaneous delivery. The microneedle core is additionally coated with a thin sheath structure embedding H2O2-scavenging enzyme to mitigate the injury of H2O2 toward normal tissues. The resulting microneedle patch can release insulin with rapid responsiveness under hyperglycemic conditions owing to an oxidative and acidic environment because of glucose oxidation, and can therefore effectively regulate blood glucose levels within a normal range on a chemically induced type 1 diabetic mouse model with enhanced biocompatibility

    Identification of clinically relevant dysglycemia phenotypes based on continuous glucose monitoring data from youth with type 1 diabetes and elevated hemoglobin A1c

    Get PDF
    Background/Objective: To identify and characterize subgroups of adolescents with type 1 diabetes (T1D) and elevated hemoglobin A1c (HbA1c) who share patterns in their continuous glucose monitoring (CGM) data as “dysglycemia phenotypes.”. Methods: Data were analyzed from the Flexible Lifestyles Empowering Change randomized trial. Adolescents with T1D (13-16 years, duration >1 year) and HbA1c 8% to 13% (64-119 mmol/mol) wore blinded CGM at baseline for 7 days. Participants were clustered based on eight CGM metrics measuring hypoglycemia, hyperglycemia, and glycemic variability. Clusters were characterized by their baseline features and 18 months changes in HbA1c using adjusted mixed effects models. For comparison, participants were stratified by baseline HbA1c (≀/>9.0% [75 mmol/mol]). Results: The study sample included 234 adolescents (49.8% female, baseline age 14.8 ± 1.1 years, baseline T1D duration 6.4 ± 3.7 years, baseline HbA1c 9.6% ± 1.2%, [81 ± 13 mmol/mol]). Three Dysglycemia Clusters were identified with significant differences across all CGM metrics (P <.001). Dysglycemia Cluster 3 (n = 40, 17.1%) showed severe hypoglycemia and glycemic variability with moderate hyperglycemia and had a lower baseline HbA1c than Clusters 1 and 2 (P <.001). This cluster showed increases in HbA1c over 18 months (p-for-interaction = 0.006). No other baseline characteristics were associated with Dysglycemia Clusters. High HbA1c was associated with lower pump use, greater insulin doses, more frequent blood glucose monitoring, lower motivation, and lower adherence to diabetes self-management (all P <.05). Conclusions: There are subgroups of adolescents with T1D for which glycemic control is challenged by different aspects of dysglycemia. Enhanced understanding of demographic, behavioral, and clinical characteristics that contribute to CGM-derived dysglycemia phenotypes may reveal strategies to improve treatment

    Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs

    Get PDF
    Glucose-responsive insulin delivery systems that mimic pancreatic endocrine function could enhance health and improve quality of life for people with type 1 and type 2 diabetes with reduced ÎČ-cell function. However, insulin delivery systems with rapid in vivo glucose-responsive behaviour typically have limited insulin-loading capacities and cannot be manufactured easily. Here, we show that a single removable transdermal patch, bearing microneedles loaded with insulin and a non-degradable glucose-responsive polymeric matrix, and fabricated via in situ photopolymerization, regulated blood glucose in insulin-deficient diabetic mice and minipigs (for minipigs &gt25 kg, glucose regulation lasted &gt20 h with patches of ~5 cm2). Under hyperglycaemic conditions, phenylboronic acid units within the polymeric matrix reversibly form glucose–boronate complexes that—owing to their increased negative charge—induce the swelling of the polymeric matrix and weaken the electrostatic interactions between the negatively charged insulin and polymers, promoting the rapid release of insulin. This proof-of-concept demonstration may aid the development of other translational stimuli-responsive microneedle patches for drug delivery

    Glucose transporter inhibitor-conjugated insulin mitigates hypoglycemia

    Get PDF
    Insulin therapy in the setting of type 1 and advanced type 2 diabetes is complicated by increased risk of hypoglycemia. This potentially fatal complication could be mitigated by a glucose-responsive insulin analog. We report an insulin-facilitated glucose transporter (Glut) inhibitor conjugate, in which the insulin molecule is rendered glucose-responsive via conjugation to an inhibitor of Glut. The binding affinity of this insulin analog to endogenous Glut is modulated by plasma and tissue glucose levels. In hyperglycemic conditions (e.g., uncontrolled diabetes or the postprandial state), the in situ-generated insulin analog−Glut complex is driven to dissociate, freeing the insulin analog and glucose-accessible Glut to restore normoglycemia. Upon overdose, enhanced binding of insulin analog to Glut suppresses the glucose transport activity of Glut to attenuate further uptake of glucose. We demonstrate the ability of this insulin conjugate to regulate blood glucose levels within a normal range while mitigating the risk of hypoglycemia in a type 1 diabetic mouse model
    corecore